ALL

GIGAcontrol-A operating profiles

SOMMER offers control profiles in the GIGAcontrol-A controllers from firmware version 3.7.

As an installer we are more often confronted with a series of parameters that are identical for each installation. To set such a range of parameters quickly, SOMMER has added control profiles to the controllers. Via a quick start menu you can immediately set frequently used functions.

Check your firmware version on the start-up screen of your controller.

Pre-set safety devices mean that safety edges and photocells can be connected quickly and the operation check is clearly indicated on the profile overview.

Pre-set safety devices mean that safety edges and photocells can be connected quickly and the operation check is clearly indicated on the profile overview.

Quick start-menu

Open the quick start menu by entering the password “9001“.
Then select one of the following control profiles.

Overview of GIGAcontrol-A control profiles

Profile

Operation mode

Safety features

4-Wire Photocell

2-Wire Photocell

OSE 1

OSE 2

8K2 / Pneum.Contact 1

8K2 / Pneum.Contact 2

Auto. close

Relay 2

Relay 3

Service Interval

Months

Cycles

Type of limit switch

Reversing delay

1

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

8K2: CLOSE / Full Reverse

Door status indicator CLOSE

Door status indicator OPEN

 

12 Months

20.000

2

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

CLOSE / Full Reverse

Door status indicator CLOSE

Door status indicator OPEN

 

12 Months

20.000

3

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

CLOSE / Full Reverse

Door status indicator CLOSE

Door status indicator OPEN

 

12 Months

20.000

Profile

Operation mode

Safety features

4-Wire Photocell

2-Wire Photocell

OSE 1

OSE 2

8K2 / Pneum.Contact 1

8K2 / Pneum.Contact 2

Auto. close

Relay 2

Relay 3

Service Interval

Months

Cycles

Type of limit switch

Reversing delay

4

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

8K2: CLOSE / Full Reverse

Warning light

Door status indicator OPEN

 

12 Months

20.000

5

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

CLOSE / Full Reverse

Warning light

Door status indicator OPEN

 

12 Months

20.000

6

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

CLOSE / Full Reverse

15 s

Warning light

Door status indicator OPEN

 

Profile

Operation mode

Safety features

4-Wire Photocell

2-Wire Photocell

OSE 1

OSE 2

8K2 / Pneum.Contact 1

8K2 / Pneum.Contact 2

Auto. close

Relay 2

Relay 3

Service Interval

Months

Cycles

Type of limit switch

Reversing delay

7

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

Pneum. : CLOSE / Full Reverse

Door status indicator CLOSE

Door status indicator OPEN

 

12 Months

20.000

Profile

Operation mode

Safety features

4-Wire Photocell

2-Wire Photocell

OSE 1

OSE 2

8K2 / Pneum.Contact 1

8K2 / Pneum.Contact 2

Auto. close

Relay 2

Relay 3

Service Interval

Months

Cycles

Type of limit switch

Reversing delay

8

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

8K2 : CLOSE / Full Reverse

15 s

Warning light

Door status indicator OPEN

 

750 ms

Profile

Operation mode

Safety features

4-Wire Photocell

2-Wire Photocell

OSE 1

OSE 2

8K2 / Pneum.Contact 1

8K2 / Pneum.Contact 2

Auto. close

Relay 2

Relay 3

Service Interval

Months

Cycles

Type of limit switch

Reversing delay

9

Pulse OPEN / CLOSE

 

not tested CLOSE / Full Reverse

8K2 : CLOSE / Full Reverse

Door status indicator CLOSE

Door status indicator OPEN

 

12 Months

20.000

Mechanical

Profile

Operation mode

Safety features

4-Wire Photocell

2-Wire Photocell

OSE 1

OSE 2

8K2 / Pneum.Contact 1

8K2 / Pneum.Contact 2

Auto. close

Relay 2

Relay 3

Service Interval

Months

Cycles

Type of limit switch

Reversing delay

10

Pulse OPEN / CLOSE

 

Tested with retraction protection

 CLOSE / Full Reverse

 CLOSE / Full Reverse

Retraction protection

Warning light

Door status indicator OPEN

 

12 Months

20.000

The English manual for the GIGAcontrol can be found here:

https://downloads.sommer.eu/files/GIGAcontrol-A30_46819V001.pdf